Project

General

Profile

Statistics
| Revision:
Name Size Revision Age Author Comment
  dbadapter 5030 about 15 years daigle Change location of PropertyService to propertie...
  metacat 7344 over 12 years ben leinfelder only lock the missing pid event if we know we h...
  protocols 3077 about 18 years Matt Jones Removed the @release@ ant token from all files ...
  shared 5015 over 15 years daigle Create database and shared directories for data...

Latest revisions

# Date Author Comment
7344 08/03/2012 10:41 AM ben leinfelder

only lock the missing pid event if we know we have it locally to contribute.
https://redmine.dataone.org/issues/3117

7343 08/03/2012 09:26 AM Chris Jones

Add locking to the itemAdded() method so ideally only one CN will respond to the request for a 'wanted' pid from the cluster. The lock is on a string, not the pid, and so won't conflict with system metadata locking. The string is based on the pid, with "missing-" as a prefix.

7342 08/03/2012 08:53 AM ben leinfelder

only publish to the missing pid "wanted list" when resynching system metadata. we were seeing redundant entry added/updated events when looking up the shared systemmetadata first.

7341 08/02/2012 10:18 PM ben leinfelder

print the missing pid count, not the total shared pid count so we know how many will be processed.

7340 08/02/2012 05:50 PM ben leinfelder

change the system metadata resynch approach: nodes will publish PIDs that they are missing after inspecting the shared identifier set. other nodes will be listening for the "wanted" pids and will put their local copy of SystemMetadata on the shared SM map. This should dramatically decrease the hazelcast chatter during a resynch and targets only the pids that are missing from any of the various nodes.

7339 08/01/2012 10:40 PM ben leinfelder

logging for processing identifier set on restart.

7338 08/01/2012 07:00 PM ben leinfelder

remove possibility for infinite loop in case data replication is not configured for the server and a data file is encountered (yikes!)

7337 08/01/2012 05:33 PM ben leinfelder

added logging debug statements to see where the replication timeout might be occurring.

7331 07/26/2012 04:26 PM ben leinfelder

check for null archived flag in ORE SM
https://redmine.dataone.org/issues/3046

7330 07/26/2012 12:08 PM ben leinfelder

check if the caller is the Node admin (the member node calling itself) as well as the existing check for the CN calling the service. Both of those callers should be given full admin rights.

View revisions

Also available in: Atom