Bug #3051

closed

standardUnit restriction doesnt match eml-unitDictionary.xml

Added by Margaret O'Brien almost 17 years ago. Updated about 16 years ago.

Status:
Resolved
Priority:
Normal
Category:
eml - general bugs
Target version:
Start date:
01/02/2008
Due date:
% Done:

0%

Estimated time:
Bugzilla-Id:
3051

Description

Entered on behalf of James Conners (@CCE/PAL LTERs)

paraphrased from his email:
In the current EML-2.0.1 schema (eml-attribute.xsd) the restricted set of values allowed for a standardUnit doesn't exactly match up with what's in the unit definitions document shipped with eml2.0.1(eml-unitDictionary.xml). There are two <unit> definitions (numberPerLiter and numberPerMilliliter) in eml-unitDictionary.xml that aren't listed as allowable for the <standardUnit> element in eml-attribute.xsd (Otherwise these lists match up correctly).

Actions #1

Updated by ben leinfelder over 16 years ago

adding those two units to the eml-attribute.xsd file

Actions #2

Updated by Margaret O'Brien over 16 years ago

eml-attribute.xsd needed a small change to fix but 2703. Since that bug is targeted for eml201, and this one (3051) for 2.1, I removed the 2 lines below. They can be added back in for a later release (thanks, Ben)

&lt;xs:enumeration value="milligramsPerLiter"/&gt;
&lt;xs:enumeration value="numberPerLiter"/&gt;
Actions #3

Updated by Margaret O'Brien about 16 years ago

changing status to "fixed"

Actions #4

Updated by Redmine Admin over 11 years ago

Original Bugzilla ID was 3051

Actions

Also available in: Atom PDF