Bug #4630
closed
creating and changing relations don't trigger LSID bump
Added by Oliver Soong almost 15 years ago.
Updated almost 15 years ago.
Description
Make a workflow with at least 3 ports and only 2 connected. Check the LSID. Now move a relation from one port to another. The LSID is the same.
Creating relations also does not trigger an LSID bump. For some reason, deleting them does.
For now I've allowed manually bumping the LSID revision and Object ID from the LSID Viewer panel so there's at least a workaround for cases like this.
Workflow LSID revision is now being updated when creating, editing, deleting, or moving relations. It is somewhat non-ideal at the moment because the lsid rolls both when the user starts the relation and ends the relation but I see no way around it at the moment and it's really not a big deal to bump the revision twice for creating a relation. Closing this bug out for now.
Original Bugzilla ID was 4630